REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
CodeOneDescriptionAmountPrice (€)Amount (€)Impact of labor (€)Labor (h)Impact of labor (%)
RE0298u

Modeling of a structure's behavior (10 UI)

1,002.242,682.242,682.125,2979,7594,77
Modeling of the behavior of a wooden, steel, reinforced or mixed concrete, including its foundation, for a building or premises with 10 inspection units, consisting of the calculation of requests, tensions and deformations derived from the l 'Application of the actions provided for by their use and the corresponding regulations, based on the data obtained in a previous campaign of determination of geometry, inspection and documentation of fissuration and deformations of the current state, execution of coves and laboratory tests , and check the security coefficients arising from this analysis. Includes: Analysis of documentation on current state, visit of the Calculista technician for inspection of the property (with a minimum inspection intensity of 6 inspection units), calculation memory and graphic support information, conclusions and recommendations. It does not include the definition, where appropriate, of the reinforcement or maintenance of the structure, which will be the subject of the corresponding execution project, nor the direction or technical assistance in the execution phase.
%01a%Auxiliary costs on the labor0,0239,66
%02%Indirect costs0,0359,48
%Estimation of the degree of difficulty or uncertainty (normal: 1.00)1,00
MOU0064hTechnical assistant. Professional level V (Source: IVE). / More information22,0020,58452,76452,7622,00
MOU0068hSpecialist technician. Professional level II (Source: IVE). / More information40,0030,001.200,001.200,0040,00
MOU0081hTechnical director. Professional level II (Source: IVE). / More information11,0030,00330,00330,0011,00
RE0156uRecognition visit, data collection, eye inspection or face -to -face intervention, even travel1,0068,8868,8855,002,50
RE0159uDedication of a technician to the eye recognition of an inspection unit in building or premises, without displacement6,0011,5569,3066,003,00
RE0272uDedication of staff to administrative management of a file1,2518,0822,6021,531,25
Remarks:
Each accessible and covered space is considered an independent inspection unit (home, shopping premises, warehouse, parking, common element or any other use), up to 200 m² of built area or fraction, at the same level . The peritation of the structural elements is subject to the availability of sufficient data on the resistance of structure materials, conservation status, dimension of structural elements, etc. This price includes a single modeling of the structure; Each subsequent modeling, with modification of the starting data, will be evaluated by 25% of the price of the first modeling.
Written by Joaquim Iborra Posadas
Company: REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
Update 20/04/2018
Zone València
Remarks:
..........
Validated by
Profile
Validated by date
Remarks:
edit price