REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
CodeOneDescriptionAmountPrice (€)Amount (€)Impact of labor (€)Labor (h)Impact of labor (%)
RE0302m

Formed Herm System Structural Reinforcement CR Din 289/R 100x100x4.

1,00146,12146,1255,813,7838,19
The wrought reinforcement consisting of: - Sodrat of the area affected by the repair, to be necessary. - Demolition of the affected partition at a height of not more than 35-40 cm. (Withdrawal, loading and transportation of Broady to the landfill) Even the replacement of once the reinforcement has been made. - Coating of Viguet cut to all its length, removal of waste, load and transport of waste to landfill. - Affected electricity device or plumbing installations. - Elevation of materials. - Printing of the lower face of the vigue concrete with epoxy resins Sikadur 32. - Placement in the concrete beam of each row of connectors of 70 mm long bath in the epoxy resins. - Placement with a chemical anchor of the postage metal plates of the commercial house Herm S.A. - Placement of the metal steel profile with galvanized tubes of 100x100x4 and 90x90x4 with 2 rows of upper metal connectors - Herm D.I.T. 289 (joined by fixing screws with a minimum of 45 cm embedded 10 mm AEH -B500SD, on each side of the union between extensible stages - Deletion of the piece - Protection of metal elements (profiles and plates) by projection of rock wool or similar with a minimum thickness of 3-4 cm along its contour.
%01a%Auxiliary costs on the labor0,020,54
%02%Indirect costs0,032,77
%Estimation of the degree of difficulty or uncertainty (normal: 1.00)1,00
RE0301uSupply and placement Herm finger-289 anchor plate.0,5432,6417,632,770,17
RE0141mPlaster chopper of the lower face of the mouth1,003,683,683,500,37
REU0256mBeam extendable Herm finger 289, 100x100x4 and 90x90x4 galvanized tubular profile, with two rows of upper metal connectors1,0033,0033,00
RE0144Running of horizontal slab shoring0,5021,8310,929,680,60
RE0143mVigue concrete structural loss of health.1,0018,2818,2812,820,94
REU0258uAffected electricity or plumbing facility device when installing0,2514,003,50
REU0257mDemolition of the partition for the opening of holes to the inmates, the Herm reinforcement system called 289, even connected and replaced and ending with the plaster coating.0,1516,002,40
REU0253kgMorter Sikatop 122/s, I go 28 kg.6,201,599,86
REU0259kgSikadur 32 FIXA BRIDGE UNION RETRENGE FORGED BOist0,0126,710,21
REU0260uM6X70 HERM Did 289 System Connector5,000,080,40
REU0254uApplying Pistols System Finger 2890,1033,003,17
REU0255uBring to Work Herms finger 2892,151,352,90
REU0262Metal profiles ignored with EF90 mineral fibers and average thickness of 3-4 cm.0,4024,559,82
MOU0005h1st officer under construction. Professional level VIII (Source: IVE). / More information0,7517,9313,4513,450,75
MOU0006hOrdinary pawn under construction. Professional level XII (Source: IVE). / More information0,9514,3113,5913,590,95
Company: REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
Update 27/11/2013
Zone València
Remarks: Notes de l'autor?
..........
Validated by ?
Profile Notes del validador?
Validated by date 00/00/0000
Remarks: Notes del validador?
edit price