REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
CODEUDESCRIPTIONQUANTITYPRICE (€)Amount (€)IMPACT OF LABOR (€)MANPOWER (H)IMPACT OF LABOR (%)
RE0305m

Reinforcing wrought profile IPE-120/140

1,00125,14125,1457,083,8645,61
Reinforcing wrought comprised: - Shoring of the affected area to repair, if necessary. - Demolition of walls affected a height not exceeding 35-40 cm. (Removal of debris, loading and transport to landfill) even replacement of the same and other once the reinforcement. - Chopped coating beams along the entire length, removal of debris, loading and transporting debris to landfill. - Diverting electricity or plumbing installations affected. - Lifting materials. - Placement with ancleje chemical metal plates posttensió model SP3500 home HERMS com- mercial S.A. by anchor studs previous location pachòmetre with armor, seated upon layer of mortar without retraction - Installation of metal profile steel A-42b with slight pressure and shoring up spilled mortar on the upper wings. - Removal of shoring. - Painted beams and plates of at least 70 micron layer of primer anti-corrosive zinc phosphate, prior review and adjustment by hand soldering. - Repainting final clorocautxú with minimum thickness of 60 microns. - Protection of metallic elements (profiles and plates) by projection of rock wool or similar with a minimum thickness of 3 cm. in all its contour. Note: Profiles metallic reinforcement will IPE140 for lamps of up to 3.60 m, IPE160 for lights between 3.60 and 4.20 m, IPE180 for lights between 4.20 and 4.90 m, for IPE200 lamps than 4.90 m.
%01a%Ancillary costs of labor0,020,71
%02%indirect costs0,032,06
%Estimating the degree of difficulty or uncertainty (normal 1.00)1,00
RE0135uSupply and installation anchor plate HERMS0,6644,5829,423,740,22
RE0141mPerforated gypsum underside of the beam1,003,683,683,500,37
RE0144Shoring concrete beam forged.0,455,332,401,740,11
RE0143mHealthy structural concrete beam underside.1,0018,2818,2812,820,94
REU0258uDiverting electricity or plumbing installations affected installing reinforcement beams0,2514,003,50
REU0257mDemolition of walls to open hollow beams interns reinforcement system Herms DIT 289, including capping and replacement of it, lining and finished with plastering.0,1516,002,40
REU0031kgMortar structural resins, Aplicatec R4 product in bags of 25 kg.5,250,653,41
REU0173kgRolled steel UNE-EN 10025 S-275-JR simple piece of hot rolled series IPN, IPE, HEB, HEA, HEM and UPN, worked in the workshop, applied structural reinforcements.12,940,7910,22
REU0030kgPainting house TKROM can 25kg, primer antocorrosiva S / R Gray 411 or similar.1,552,093,24
REU0161kgSolvent universal primer TKROM antixidante can 5 kg.0,021,770,04
REU0032mFireproof mineral wool fibers projected on profile IPE-120.0,8212,8010,50
MOU0005hOfficial 1st in construction. Professional level VIII (Source: IVE). / More information0,9717,9317,3917,390,97
MOU0006hOrdinary laborer in construction. Professional XII (Source: IVE). / More information1,2514,3117,8917,891,25
company: REHABI-LI-TAR. Gestió i promoció de la rehabilitació SLU
update 27/11/2013
zone València
observations: Notes de l'autor?
..........
Validated by ?
profile Notes del validador?
Validated date 00/00/0000
observations: Notes del validador?
Edit price