Plumbing

CODEUDESCRIPTIONPRICE
RE0030m

Lifted collector buried PVC pipe.

Lifted buried collectors, and even retired truck or cargo container.

5,56 €
RE0365m

Lowering of water evacuation tube sheet of zinc, 80 mm in diameter.

Lowering of water evacuation tube sheet of zinc and 80 mm diameter 0:50 mm thick, even proportion of special parts and aids palette, fully installed. Even placing parasol leaves the union to avoid embocar down. Fully placed in the position of the previous piece even mask.

59,93 €
RE0223m

Down lacquered steel storm D120

Supply and installation of lacquered steel circular down for water collection, comprising preformed pieces with rivets bonding system and the joints sealed with silicone, placed flanged metal installed outside the building. Even w / w elbows, supports and special parts. Fully assembled, with connections made and tested by the installation company by the relevant testing service (included in the price). Including assembly and dismantling scaffolding hire certified or mechanical lifting equipment for proper installation.

24,29 €
RE0333m

Lowering health series B indoors with PVC pipe 110.

Supply and installation of network down inside the evacuation of sewage, consisting of PVC pipe, series B, 110 mm in diameter and 3.2 mm thick. Even w / w auxiliary material for assembly and support the work, accessories and special pieces placed by union attached with adhesive. Fully assembled, with connections made and tested by the installation company by the relevant testing service (included in the price)

20,80 €
RE0332m

Lowering health series B indoors with PVC-pipe 125.

Supply and installation of network down inside the evacuation of sewage, consisting of PVC pipe, series B, 125 mm in diameter and 3.2 mm thick. Even w / w auxiliary material for assembly and support the work, accessories and special pieces placed by union attached with adhesive. Fully assembled, with connections made and tested by the installation company by the relevant testing service (included in the price).

23,31 €
RE0331m

Lowering health series B indoors with PVC-pipe 160.

Supply and installation of network down inside the evacuation of sewage, consisting of PVC pipe, series B, 160 mm in diameter and 3.2 mm thick. Even w / w auxiliary material for assembly and support the work, accessories and special pieces placed by union attached with adhesive. Fully assembled, with connections made and tested by the installation company by the relevant testing service (included in the price).

29,19 €
RE0330m

Changing down inside PVC-160 and B-lined masonry.

Change of drainpipes consisting opening Dec. local partitions not wet (bedrooms, dining rooms ...) removing old vents, placement of new drainpipes diameter 125/160 PVC glued together, connecting drains of devices existing partitions closing of realizing through appropriate employment and replacement of siding with fiberglass mesh, even cleaning escobros loading and transport to landfill.

136,42 €
RE0513m

PVC sewer pipe buried 250-mm, filled ditch

Buried collector made with a smooth PVC pipe for sanitation, diameter 250 mm, binding thickness and glued under the UNE

RE0514m

PVC sewer pipe buried-315 mm, filled ditch

Buried collector made with a smooth PVC pipe for sanitation, diameter 350 mm, binding thickness and glued under the UNE

RE0512m

Collector buried pipe PVC-200 mm, filled ditch

Buried collector made with a smooth PVC pipe for sanitation, diameter 200 mm, binding thickness and glued under the UNE

RE0515u

Wiring collector zone of services, local

Reinstalling the installation and connection of collectors buried inside an evacuation unit for cleaning internal premises, consisting of a toilet-bowl and pedestal, made of smooth PVC pipe 40-110 mm, series B (UNE-1329-1) for the drainage network connecting these devices. Even o.g. individual referrals, connections, accessories and fasteners, wiring the fan, closer. Even o.g. concrete base mass average thickness of 10 cm in parts sections of collectors. Installation according to CTE. DB. HS safety. Preconditions support: Before beginning the activities relating to the implementation process will be conducted the following checks: will check that its location and route correspond to the Project and that there is enough space for installation and connection to the existing down. Includes presentation int. arch. tubes, special pieces, elbows, joints, fasteners, testing services, protection against shock, filling Trados perimeter arch., finishes, except for the floor finish. Training holes connected to tubes, sealing joints and inner-ext. Even in airtight hatch closure and no odor mefítics frame. There will be closure plugs at points drain until receipt of wares. Mechanical strength and tightness guaranteed. > Unit completely finished and tested its operation.

RE0506m

Demolish existing buried collectors, 110-125, patios and storage

Demolition of existing collector buried in yards and warehouses of shops, concrete or PVC, and various diameters between 110-125 mm, made with manual means and electric hammer devastating. Even w / w cleaning, gathering, removal and manual loading debris truck or container. Not considered demolishing the existing slab or pavement, worth another game.

12,78 €
RE0065m

Provision collecting water canal

Supply and installation of prefabricated gutter for water collection, polymer concrete section 20x20 / 15 galvanized grid raster unit connected to sewer with PVC pipe, pre-prepared trench opening electric hammer wedge the duct, concrete pieces and wardrobe result hearth existing finishes perimeter and cement tiles rejunte finishing, cleaning and removal of excess material

130,77 €
RE0503u

Opening of Commercial dividing bushing

Opening holes interns for the implementation of the new network of collectors buried at the meeting with the partitions dividing or distribuició interior, made from solid or hollow ceramic brick with rubble removal and loading portable container located on public roads.

26,61 €
RE0508

Opening and digging wells for new boxes

Opening and digging wells for the new network of underground sewers, manholes training walk down and step inside width variable between 50x50 and 80x80 cm. and average depth of 0.75 / 0.90 m, including manual removal of the existing land and container cargo placed laptop in public, o.g. layouts, elevations and earrings set average level of 2% since places of origin foot and lower end evacuation. Unit executed and fully prepared for the collector pipe.

47,78 €
RE0509u

Pericó walk down, 50X50 cm.

Pericó registrable walk down, underground network of collectors, interior dimensions of 50x50x60 cm, 24x12x11 cm honeycomb made of brick and cement mortar 1: 6-bed on concrete base hm-20 / B / 20 / and thickness of 12 cm, plastered burnished previously mortar waterproof 1: 6, rounded edges and painted with asphalt emulsion, received piping and closing top with hatch frame and precast concrete, even proportion of referrals individual connection down accessories. Installation according to CTE. DB. HS safety. Preconditions support: Before beginning the activities relating to the implementation process will be conducted the following checks: will check that its location and route correspond to the Project and that there is enough space for installation and connection to the existing down. Includes presentation inside the chest tubes, special pieces, elbows, joints, fasteners, testing services, protection against shock, filling Trados perimeter arch., Finishes, except for the floor finish. Training holes connected to tubes, sealing joints and interior-exterior. Even in airtight closure hatch frame and the passage of odors mefítics

142,14 €
RE0511u

Pericó walk cranes inside of 75x75 cm

Pericó foot front line, inside the building, before the network connection via public sewer for the underground network of collectors interiors, interior dimensions of 75x75, profunidad average 1.10 m, Trappe 40 x40 cm, made of brick honeycomb 24x12x11 cm, with cement mortar 1: 6 on a bed-slab concrete hm-20 / B / 20 / i thick 12 cm, plastered burnished inwardly mortar waterproof 1: 6, rounded edges and painted with asphalt emulsion, received superior piping and closing with hatch frame and cast even proportion of referrals individual accessories. Installation according to CTE. DB. HS safety. Preconditions support: Before beginning the activities relating to the implementation process will be conducted the following checks: will check that its location and route correspond to the Project and that there is enough space for installation and connection to the existing down. Includes presentation inside the chest tubes, special pieces, elbows, joints, fasteners, testing services, protection against shock, filling Trados perimeter arch., Finishes, except for the floor finish. Training holes connected to tubes, sealing joints and interior-exterior. Even in airtight hatch closure and no odor mefítics frame.

206,10 €
RE0510u

Forensics step in secondary network of 60x70 cm

Not registrable expertise, network of underground collectors, interior dimensions 60x70X75 cm, 24x12x11 cm honeycomb made of brick and cement mortar 1: 6-bed on concrete base hm-20 / B / 20 / I 12 cm thick, plastered burnished previously waterproofed mortar 1: 6, with rounded edges and painted asphalt emulsion, received superior piping and closing with hatch frame and precast concrete, even proportion of referrals individual accessories. Installation according to CTE. DB. HS safety. Preconditions support: Before beginning the activities relating to the implementation process will be conducted the following checks: will check that its location and route correspond to the Project and that there is enough space for installation and connection to the existing down. Includes presentation inside the chest tubes, special pieces, joints, fasteners, testing services, protection against shock, filling Trados chest perimeter, finishes, except for the floor finish. Training holes connected to tubes, sealing joints and interior-exterior. Even in airtight hatch closure and no odor mefítics frame.

163,46 €